Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0367419940370070946
Journal of Korean Pediatric Society
1994 Volume.37 No. 7 p.946 ~ p.952
Nonspecific Bronchial Reactivity Determined by Tidal Breathing Method and Chest Auscultation -A Comparison with Dosimeter Method-


Abstract
As a preliminary step to determine if we can perform methacholine challenge test in young children, We investigated the feasibility of modified technique of methacholine challenge test in which tidal breathing and chest auscultation were used
instead of
dosimeter and measurement of lung function in older children.
@ES The results are as follows:
@EN 1) Values of PC20 measured by the tidal breathing method correlated significantly with those of PC20 measured by dosimeter
2) Ratio of values (PC20) obtained wth both methods was not related to age.
3) The minimal concentration of methacholine which caused wheezing on chest ausculation (PCW) correlated closely with PC20, but was 44% greater on average.
4) Expiratory wheezing is associated with greater fall of FEVI from baseline than inspiratory wheezing.
Thus wheezing on chest auscultation can be used to detect bronchial obstruction at the end point for bronchial provocation testing in older children during the quiet tidal inhalation of methacholine. This may be applied to measurement of airway
reactivity in young children who are unable to perform routine pulmonary function tests.
KEYWORD
FullTexts / Linksout information
Listed journal information
KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø