Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0369820060360010023
Jorunal of Korean Pharmaceutical Sciences
2006 Volume.36 No. 1 p.23 ~ p.29
Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human
Á¶Çý¿µ/Cho HY
°­Çö¾Æ/ÀÌÈ­Á¤/ÃÖÈıÕ/À̿뺹/Kang HA/Lee HJ/Choi HK/Lee YB
Abstract
A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by 33 factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at ?80?C for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.
KEYWORD
Promethazine, Human serum, Validation, Pharmacokinetics, HPLC
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)