Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0371019870200020255
Journal of Preventive Medicine and Public Health
1987 Volume.20 No. 2 p.255 ~ p.260
Relationship between the Measurement Values of the Digital Dust Indicator and Personal Dust Sampler
À±¿µ³ë/Yoon YN
ÀÌÁ¤ÁÖ/Á¤È£±Ù/ÃÖÈ£Ãá/Lee JJ/Chung HK/Choi HC
Abstract
The digital dust indicator (Sibata P-5), one of the direct-reading instruments was evaluated for the respirable dust in the underground coal mine environments. As a reference, respirable dust was determined using three cyclones and/or impactors. All the tests were performed on aerosol in twenty underground coal mines. The coefficients of mass-relative concentration were 0.067¡¾0.054 (Mean¡¾ Standard deviation) (range: 0.006-0.172). The relationship between relative concentration and temperature was not significant statistically. Also, the relationship of relative concentration and relative humidity was not significant. Mass concentration and relative concentration were 5.31¡¾5.22 mg/m3 and 162¡¾163 CPM (Mean¡¾Standard deviation) respectively. The range of mass concentration was 1.22-22.69 mg/mt relative concentration 16-628 CPM. The relationship of mass concentration and relative concentration was not significnat in these ranges.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø