Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0374019940170040371
Ewha Medical Journal
1994 Volume.17 No. 4 p.371 ~ p.376
The Influence o Contact Lens Wearing of Rear Film



Abstract
Clinically, the diagnostic methods of dry eye and adaptation of contact lens wearing have been the slit lamp examination, tear film break up time (BUT) measurement and Schirmer test. There have been reports that Cchirmer test and BUT measurement
can be
influenced by may factors, especially the mothods of measuring it. So the question of their repeatability and reproducibility has not yet been solved.
We studied the influence of contact lens wearing on the tear film by phenol red thread test between contact lens wearers and non-wearers.
@ES The results as follows:
@EN 1) The mean vale measured by the PRT method was 13.92¡¾7.68 mm in right eye, 15.03¡¾7.66 mm in left eye among the contact lens wearing group and 22.40¡¾6.54mm in right eye, 21.48¡¾6.30 mm in left eye among the contact lens-non wearing group.
2) There was statically significant decreased value of PRT in the contact lens wearing group.
3) There was not statistically significant difference between contact lens type, duration of contact lens wearing, duration of exchanging of contact lens, contact lens wearing time per one day.
KEYWORD
FullTexts / Linksout information
Listed journal information