This study was carried out to evaluate the mechanical effects of human mandible under various loading condition. The experimental strain analysis of a mandible was performed by using straing gauge and photoelatic coating method.
@ES The results results obtained were summarized as follows:
@EN 1. The tendency of fracture was low in the mandible under vertical load on the symphysis or the mandibular body, but high at the symphysis under lateral load on the symphysis.
2. The tendency of fracture was high at the condyle neck under vertical load on the angle.
3. The effects of stress concentration were low in the opposite mandibular body under vertical load on the mandibular body or the angle.