Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0376219990350020247
Chonnam Medical Journal
1999 Volume.35 No. 2 p.247 ~ p.256
MR Cholangiopancreatography: Comparsion of Single Shot Fast Spin Echo Technique and Heavily T2-weighted Fast Spin Echo Technique
Song Sang-Gook

Park Seung-Jin
Kim Sei-Jong
Kim Jae-Kyu
Chung Tae-Woong
Kim Hyun-Soo
Park Jin-Gyoon
Yoon Jong-Hoon
Kim Yun-Hyun
Jeong Yong-Yeon
Seo Jeong-Jin
Jeong Gwang-Woo
Kang Heoung-Keun
Kim Heoung-Kil
Abstract
The purpose of this study is to compare the usefulness of single shot fast spin echo(SSFSE) sequence and heavily T2-weighted fast spin echo(FSE) sequence in magnetic resonance cholangiopancreatography(MRCP) in the diagnosis of pancreatobiliary diseases. Twenty-eight patients with suspected pancreatobiliary diseases were examined on 1.5T MR scanner using single- and multi-slice SSFSE and FSE technique. FSE images were obtained with 4 mm slice thickness and reconstructed using maximum intensity projection. The data acquisition techniques of SSFSE were as follows : 1) single-slice acquisition with 80 mm slice thickness, 2) multi-slice (8 slices) acquisition with 10 mm slice thickness, followed by maximum intensity projection. Two radiologists evaluated the MRCP images using the three techniques qualitatively and quantitatively. The results were as follows. For visual conspicuity of hilum of both intrahepatic bile duct, multi-slice SSFSE was superior to single-slice SSFSE and FSE(p< .05). However, for pancreatic duct, single-slice SSFSE was superior to multi-slice SSFSE and FSE(p< .05). But there were no statistically significant differences in visualization of other biliary structures(p> .05). The overall image quality with multi-slice SSFSE was significantly better than that with single-slice SSFSE and FSE(p> .05). For diagnosis of causative lesion, there were no significant differences in three techniques. For quantitative assessment, contrast ratio was the highest in single-slice SSFSE, but statistically not significant(p> .05) and contrast-to-noise ratio was the highest in multi-slice SSFSE, statistically significant(p< .05). In conclusion, SSFSE technique not only provides better conspicuity of intrahepatic bile duct and pancreatic duct with very short scan time, but also gives no difference in iagnosis of causative lesion than does FSE in MRCP . Especially multi-slice SSFSE gives excellent image quality, and is subsequently essential in diagnosis of the patients with marked bile duct dilatation. Also, single-slice SSFSE can be very useful for evaluation of pancreatic duct lesion.
KEYWORD
Bile ducts, MR, Magnetic resonance(MR), pulse sequence, technology, Pancreas
FullTexts / Linksout information
Listed journal information