Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0377619620020030273
Korean Jungang Medical Journal
1962 Volume.2 No. 3 p.273 ~ p.278
Study on the electrocardiographic exercise test



Abstract
Recently Lepeschkin reproted a new method to anlayse the electrocardiogram after exercise, test and which was reported as a better method than master¢¥s.
Authors studies the electrocardiographic exercise test of 50 normal indiuiduals using the Lepeschkin¢¥s new method to evaluate this new method.
The result showed that the Lepeschkin¢¥s method of analysis contained less frequent false positive case (4% in single and double two-step test) than those of master (6% in single criteria to request continuation of 2 minutes was lese rigidly requested by. Lepeschkin¢¥s method is a more reliable method than master¢¥s.