1974 Volume.17 No. 4 p.447 ~ p.450
T 4 Kit Method for Thyroid Function Tests (Report 4)


Abstract
The serum thyroxine levels were determined by competitive pretein binding analysis using Tetrasorb 1251 Kit in 1.102 cases with various thyroidal states and the reproducibility of T 4 test was studied in 103 cases.
Followings were the results:
1. The mean values of T-4 test were 9.1¡¾2.8 ug/dl in 776 euthyroid cases, 19.41¡¾4.41ug/dl in 297 hyperthyroid cases and 3.6¡¾2.4ug/dl in 29 hypothyroid cases.
2. The diagnostic compatibilities of T-4 test were 90.3% in 776 euthyroid cases, 89.9% in 297 hyperthyroid cases and 84.1% in 29 hypothyroid cases. The diagnostic compatibility of the overall cases was 89.7%.
3. The reproducibility of T-4 test was studied with 103 samplings (103 cases). The difference of -averaged absolute values were 0.84ug/dl in 73 euthyroid cases, 0.47uiug/dl in 27 hyperthyroid cases and 1.1ug/dl in 3 hypothyroid cases. The average difference of absolute value in the overall cases was 0.751ug/dl.
4. It is again conformed that the T-4 test has a higher diagnostic accuracy than those of the conventional methods in various thyroid diseases.
KEYWORD
FullTexts / Linksout information