Diagnosis of Trace Toxic Uranium Ions in Organic Liver Cell
Ly Suw-Young

Pack Eun-Chul
Choi Dal-Woong
Abstract
Uranium is toxic and radioactive traces of it can be found in natural water and soils. High concentrations of it in biological systems cause genetic disorders and diseases. For the in vivo diagnosis, micro and nano range detection limits are required. Here, an electrochemical assay for trace toxic uranium was searched using stripping voltammetry. Renewable and simplified graphite pencils electrode (PE) was used in a three-electrode cell system. Seawater was used instead of an electrolyte solution. This setup can yield good results and the detection limit was attained to be at 10 ¥ìgL?1. The developed skill can be applied to organic liver cell.
KEYWORD
Uranium, Voltammetry, Fish¡¯s liver, Fluorine