A Study on the Simultaneous Removal of Organics and Nutrients in Upflow Packed Bed Column Reactor
Seon Yong-Ho

Abstract
Biofilm process is preferred to activated sludge process in small domestic wastewater treatment plant because of its simplicity in operation and maintenance. Column reactor filled with waste ceramics and with waste plastics was used to remove pollutants in restaurant wastewater. COD removal at 18 hours of hydraulic retention time (HRT) gave 93.7%, COD removal during the experimental period, where maximum COD removal was observed. Under same condition, average removal of total nitrogen and total phosphorus were 82.3% and 25.9%, respectively Organic and nitrogen were efficiently removed with the HRT of 18 hours or more.
KEYWORD
Simultaneous removal, organics and nutrients, upflow packed bed column reactor, HRT, COD, T-N, T-P