KMID : 0380620100420060648
|
|
Korean Journal of Food Science and Technology 2010 Volume.42 No. 6 p.648 ~ p.652
|
|
Detection of Different Ratios of Gamma-irradiated Turmeric by Photostimulated Luminescence and Thermoluminescence
|
|
Lee Ji-Ae
Chung Hyung-Wook Kwon Joong-Ho
|
|
Abstract
|
|
|
This study was performed to investigate PSL and TL characteristics for the detection of different ratios of gamma-irradiated turmeric. It was possible to determine PSL and TL of 1- and 10-kGy irradiated turmeric. The TL ratios (TL1/TL2) of non-irradiated samples were lower than 0.001, while those of irradiated samples were higher than 0.355. In the PSL results, blended samples containing irradiated ingredients showed intermediate values for a 1% blending rate. Furthermore, TL analysis of blended samples seems to offer a promising method for irradiation identification by TL glow curve form and temperature range. The 1- and 10-kGy irradiated samples were able to be detected above a 4% blending rate. However, the TL ratio appeared as a threshold value below 0.1 for irradiated samples. Overall, TL analysis identified 4% blended samples containing gamma-irradiated turmeric.
|
|
KEYWORD
|
|
turmeric, gamma-irradiated, blending, ratio, PSL, TL
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|