Rapid analytical method of the polychlorinated biphenyls in PCBs containing liquid wastes
Shin Sun-Kyoung

Jeon Tae-Wan
Yoon Jeong-Ke
Kim Tae-Seung
Oh Gi-Jong
Kim Young-Sik
Kim Kyoung-Soo
Abstract
The study on the development of rapid analytical method of PCBs containing waste was performed by considering the extraction, column cleanup process, analytical condition and so on. In the established method, new sample clean-up procedure, new quantification peaks and temperature program were introduced. Method detection limit of the method was 0.5 §·/L, and the method could save the total run time to 2/3, therefore save the analysis cost, The new rapid analytical method of transformer oil was suggested to the waste official test method.
KEYWORD
rapid method, PCBs containing waste, liquid waste, GC/ECD