Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385520090220030191
Analytical Science & Technology
2009 Volume.22 No. 3 p.191 ~ p.200
Study on establishment of emission cell test method for liquid phase building materials
Lim Jeong-Yun

Jang Seong-Ki
Seo Soo-Yun
Abstract
The aim of this study was to evaluate and establish of emission test method for liquid phase building materials such as paint, adhesive, sealant by emission cell. A small-scale emission chamber and emission cell were used to evaluate emission of TVOC from paint, adhesive, sealant. The quantity of TVOC emission were measured by a gas chromatography/mass spectrometry (GC/MS). Background concentration of TVOC was below 10 §¶/§© in the emission chamber and cell. Air tightness and recovery in chamber and cell showed good results. The recovery of thermal desorber for toluene and n-dodecane were about 120%. The repeatability of response factor and retention time in GC/MS below 30%. The method detection limit of VOCs ranged 0.04~8.82 ng. The concentration of TVOC emission using emission cell was 1.35~1.41 times higher than emission chamber. The correlation of TVOC emission using chamber and cell method was significantly high (r=0.91~0.97).
KEYWORD
liquid phase building materials, TVOC, small-scale emission chamber, emission cell, correlation
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)