Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385520090220060458
Analytical Science & Technology
2009 Volume.22 No. 6 p.458 ~ p.463
Determination of residual flumethrin in honey products by HPLC
Won So-Young

Jeong Young-Ji
Lee Hwee-Jae
Chang Hye-Sook
Ban Kyeong-Nyeo
Kang Ho-Il
Kim So-Hee
Abstract
A new quantitative analytical method has been established for the rapid determination of flumethrin in honey products using high performance liquid chromatography (HPLC). Sample was dissolved and extracted in the mixture of water and acetonitrile (1:2). The extracts were purified with silica cartridge eluted by the mixture of hexane and dichloromethane (55:45) and analyzed at 266 §¬ using HPLC. The percentage recovery of flumethrin spiked in sample was found to be 90.2-97.8% and the limit of detection is 0.003 §·/§¸. We validated the method for the linearity, the precision and the reproducibility. We investigated the residues of flumethrin in honey products retailed in market using the established method. Flumethrin was not detected at all among 130 samples of honey.
KEYWORD
flumethrin, honey, mite, acaricide, HPLC
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)