KMID : 0385520100230020147
|
|
Analytical Science & Technology 2010 Volume.23 No. 2 p.147 ~ p.154
|
|
Characteristics of tamiflu occurrence in surface water using LC/MS/MS
|
|
Shin Sun-Kyoung
Kang Young-Yeul Park Jin-Soo Koo So-Hyun Hwang Seung-Ryul Kim Woo-Il Song Ki-Bong Kim Young-Hee Kim Tae-Seung Han Jin-Seok
|
|
Abstract
|
|
|
Oseltamivir carboxylate (OC) and Oseltamivir ethylester (OE) were analyzed to evaluate the environmental distribution in pandemic season in Korea. The detected concentration of OE was the range of 0.008~0.087 §¶/L, and OC was the range of 0.029~0.287 §¶/L. The detected concentration of OC in this study was two times higher than reported concentration of OC in river water in Japan. But, these analytical results cannot be directly compared to the previous reported concentration, because of the different sampling period.
|
|
KEYWORD
|
|
tamiflu, oseltamivir ethylester phosphate, oseltamivir ethylester, oseltamivir carboxylate, LC/MS/MS
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|