Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385520100230030278
Analytical Science & Technology
2010 Volume.23 No. 3 p.278 ~ p.283
Comparison of three analytical methods for PCBs-containing liquid wastes
Lim Kyeo-Keun

Yoon Sung-Kyu
Bae Woo-Keun
Abstract
This study was performed to compare the analytical results among L2000DX and two GC/ECD methods (rapid and conventional). 15 samples of transformer oils were collected to compare the analytical results. In the analytical results of PCBs-containing transformer oil, the PCBs concentrations were in the range of 4.4 §·/§¤ to 182.8 §·/§¤ with L2000DX, N.D. to 14.63 §·/§¤ with conventional GC/ECD, and N.D. to 13.03 §·/§¤ using rapid GC/ECD. The PCB concentrations detected with the L2000DX showed a large difference to those detected with GC/ECD methods. Otherwise, little difference was shown between the two GC/ECD methods at a concentration range lower than 4 §·/§¤, although the rapid GC/ECD method tended to detect a slightly lower concentration near the regulation criteria of Korea for 2 §·/§¤.
KEYWORD
PCBs, GC/ECD, L2000DX, transformer oil
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)