Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385520110240020119
Analytical Science & Technology
2011 Volume.24 No. 2 p.119 ~ p.126
Determination of benzene, toluene, ethylbenzene and o-xylene in bottled waters by headspace solid-phase microextraction and gas chromatography/mass spectrometry
Kim Jong-Hun

Abstract
The amount of benzene, toluene, ethylbenzene, and o-xylene (BTEX) in 30 kinds of bottled waters purchased from market and 9 kinds of tap waters from home were determined using headspace solid phase microextraction (HS-SPME). The sample was stirred at 1200 RPM G for 4 min using a magnetic bar with 100 §­ PDMS as adsorbent for BTEX. Then it was desorbed from the fiber for 1 min at room temperature. Quantitation was achieved using standard calibration method. The limit of detection was determined as benzene 0.39 (¡¾0.04) ng/§¢, toluene 0.08 (¡¾0.04) ng/§¢, ethylbenzene 0.04 (¡¾0.01) ng/§¢, and o-xylene 0.05 (¡¾0.02) ng/§¢. Benzene and o-xylene were not detected in any samples, but toluene was detected in 11 samples, and ethylbenzene was detected just in 3 samples among 30 investigated bottled waters. The concentration range of investigated materials for toluene and o-xylene were 0.24 (¡¾0.09)~2.95 (¡¾0.08) ng/§¢, 0.08 (¡¾0.06)~0.93 (¡¾0.10) ng/§¢, respectively.
KEYWORD
BTEX, bottled water, tap water, GC/MS, SPME
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)