Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385520110240040237
Analytical Science & Technology
2011 Volume.24 No. 4 p.237 ~ p.242
Analytical method development for residual metamizol in meat using LC/MS/MS
Kim Tae-Wook

Yang Yeung-Kyong
Gwoak Soon-Chul
Kang Dong-Young
Abstract
In this study, an analytical method was developed for residual metamizol in beef and pork using LC/MS/MS. 4-methylaminoantipyrin (MAA), the main metabolite of metamizol was targeted for analysis instead of its parent compound. MAA was simply extracted from meat by acetonitrile, purified and then analyzed by multiple reaction monitoring method (MRM). Standard addition method was used for calibration. The calibration curves showed the linearity of r©÷ £¾ 0.99 for both matrices included. The developed method was validated by six-time intra-lab tests and inter-lab tests with two other institutes. The validation of the whole procedure for beef showed the intra-lab accuracies of 78-102% (CV 5.5-9.1%) and the inter-lab accuracy of 98% (CV 14%); the intra-lab accuracies of 95-99% (CV 3.9-5.6%) and the inter-lab accuracy of 111% (CV 13%).
KEYWORD
LC/MS/MS, MRM, MAA, Residue