Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0385920120230020295
Journal of the Korean Society of Emergency Medicine
2012 Volume.23 No. 2 p.295 ~ p.297
A Case of Carbon Dioxide Poisoning by Malfunction of a Carbon Dioxide- Based Fire Extinguishing System
Jeong Won-Jung

So Byung-Hak
Kim Hyung-Min
Abstract
Carbon dioxide is a colorless, odorless, nonirritating gas with many practical uses. In particular, because it can displace oxygen from the environment, it is used as a fire extinguisher. We describe an incident that occurred as a result of malfunction of a carbon dioxide-based fire extinguishing system in our hospital. Twelve casualties reached our emergency department. Symptoms of exposure included nausea, dizziness, loss of consciousness, vomiting, chest discomfort, and seizure. Results of initial arterial blood gas analysis showed acidosis in five patients. A new pneumonic infiltration at the left. upper lung field was observed in one patient, while sinus tachycardia in electrocardiography (ECG) was observed in another patient. Oxygen was initially supplied to all casualties, until symptoms of intoxication had disappeared. Three patients were admitted to the hospital, but were discharged without complication. Despite occurrence of massive casualties, with significant symptoms due to unintentional exposure to high concentrations of carbon dioxide, patients` symptoms were relieved by supportive care.
KEYWORD
Carbon dioxide, Poisoning, Mass casualty incidents
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø