Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0386119930290040844
Journal of the Korean Radiological Society
1993 Volume.29 No. 4 p.844 ~ p.848
Value of Modified Foley Catheter Method in the Removal of Blunt Exophageal Foreign Bodie
±è°æÀÎ
Â÷À¯¹Ì/ÇÑ Çå/¾ç´Þ¸ð/±èÇü½Ä/ÀÌ¿µ¼®
Abstract
removal of blunt esophageal foreign bodies using Foley catheter under a fluoroscopic guidance is a well-recognized procedure. However, since this procedure is rather cumbersome and uncomfortable to the patient, the authors tried to find an easier
and
more convenient modified technique. For 10 patients with esophageal foreign body, we tried the method to the patients who is lying in the right lateral decubitus position and 3 assistants hold head. arms, trunk and legs of the patients without
tilting
the table and without using immobilizer. Foley catheter is inserted through nostril, nasal cavity and pharynx to esophagus. In order to identify the Foley catheter in esophagus, 0.025 inch short wire was inserted in the Foley catheter. The
balloon
of a
Foley catheter was inflated by 10cc of air, and the syringe was kept attached to the Foley catheter during the procedure. After passage of the foreign body through the upper esophageal sphincter, the balloon was deflated immediately and the
foreign
body
was removed through the mouth. We successfully removed in removing all the blunt esophageal foreign body with ease. This modified method is also fast, safe and efficient.
KEYWORD
FullTexts / Linksout information
Listed journal information
KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø