Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0386420120250040269
Journal of the Korean Fracture Society
2012 Volume.25 No. 4 p.269 ~ p.276
Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
Sohn Oog-Jin

Kwon Moon-Soo
Park Chul-Hyun
Abstract
Purpose: To compare results of minimally invasive plate osteosynthesis using a locking compression plate and a periarticular locking plate in distal femur fractures.

Materials and Methods: We retrospectively reviewed 31 consecutive femoral fractures who treated by minimally invasive plate osteosynthesis from April 2006 to May 2009. Sixteen patients were treated using a locking compression plate (group A) and 15 patients were treated using a periarticular locking plate (group B).

Results: The mean operation time was 78 minutes and 76 minutes (p=0.273), and the mean radiation exposure time was 1.9 minutes and 2.3 minutes (p=0.001) in the group A and B, respectively. The plate bending during operation was performed in 4 cases of group A. The knee range of motion was 117.5¡Æ and 118.2¡Æ (p=0.825), and the Lysholm score was 81.3 and 81.8 (p=0.723) in the group A and B, respectively. Schazker criteria showed more than good grade in 93.8% of group A and in 93.3% of group B (p=1.0).

Conclusion: No significant differences in clinical results were observed between the two groups. However, a lower anatomical compliance was showed in the locking compression plate, and a higher risk of radiation exposure was showed in the periarticular locking plate.
KEYWORD
Distal femoral fracture, Minimally invasive plate osteosynthesis, Locking compression plate, Periarticular locking plate
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø