KMID : 0386420120250040269
|
|
Journal of the Korean Fracture Society 2012 Volume.25 No. 4 p.269 ~ p.276
|
|
Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
|
|
Sohn Oog-Jin
Kwon Moon-Soo Park Chul-Hyun
|
|
Abstract
|
|
|
Purpose: To compare results of minimally invasive plate osteosynthesis using a locking compression plate and a periarticular locking plate in distal femur fractures.
Materials and Methods: We retrospectively reviewed 31 consecutive femoral fractures who treated by minimally invasive plate osteosynthesis from April 2006 to May 2009. Sixteen patients were treated using a locking compression plate (group A) and 15 patients were treated using a periarticular locking plate (group B).
Results: The mean operation time was 78 minutes and 76 minutes (p=0.273), and the mean radiation exposure time was 1.9 minutes and 2.3 minutes (p=0.001) in the group A and B, respectively. The plate bending during operation was performed in 4 cases of group A. The knee range of motion was 117.5¡Æ and 118.2¡Æ (p=0.825), and the Lysholm score was 81.3 and 81.8 (p=0.723) in the group A and B, respectively. Schazker criteria showed more than good grade in 93.8% of group A and in 93.3% of group B (p=1.0).
Conclusion: No significant differences in clinical results were observed between the two groups. However, a lower anatomical compliance was showed in the locking compression plate, and a higher risk of radiation exposure was showed in the periarticular locking plate.
|
|
KEYWORD
|
|
Distal femoral fracture, Minimally invasive plate osteosynthesis, Locking compression plate, Periarticular locking plate
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|