Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0386420160290030178
Journal of the Korean Fracture Society
2016 Volume.29 No. 3 p.178 ~ p.184
Orthogonal Locking Compression Plate Fixation for Distal Humeral Intraarticular Fractures
Oh Hyoung-Keun

Choo Suk-Kyu
Koh Kyoung-Hwan
Yeom Ji-Woong
Abstract
Purpose: To investigate the surgical outcomes of orthogonal locking compression plate fixation for distal humeral intraarticular fractures.

Materials and Methods: This study included 18 patients presenting a distal humeral intraarticular fracture who were treated with orthogonal locking compression plate fixation. According to the AO/OTA classification, there were eight C2 and ten C3 fractures. We evaluated radiologic outcomes, clinical results with range of motion, operation-related complications, and functional score by Mayo elbow performance score (MEPS).

Results: The a verage u nion t ime was 3.5 months, and there was no c ase of r eduction l oss of a rticular f racture at t he last follow-up. Additional surgical procedures were needed in the three cases of C3 fractures. There was one case of heterotrophic ossification and one case of K-wire irritation. The average range of motion of elbow joint was 7¡Æ to 122¡Æ, and functional results were graded as 14 excellent, three good, and one fair by MEPS.

Conclusion: Anatomical reduction and internal fixation with orthogonal locking compression plate could provide satisfactory surgical outcomes for the treatment of distal humeral intraarticular fracture.
KEYWORD
Humeral fracture, Intraarticular fracture, Fracture fixation
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø