Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0386720070190010001
Journal of the Korean Hip Society
2007 Volume.19 No. 1 p.1 ~ p.8
Primary Total Hip Arthroplstry with Cementless VerSys Femoral Stem: a Minimum 5-years follow-up
Kim Sang-Bum

Park Sang-Won
Cho Hyung Joon
Jung Nam-yeon
Abstract
Purpose: This study evaluated the clinical and radiographic results of primary total hip arthroplasty with a noncemented VerSys Fiber Metal Midcoat stem.

Materials and Methods: Thirty nine hips in thirty three patients were followed up for a minimum of five years. The clinical results were evaluated based on the Harris hip scores. Radiographic analysis of the femoral component was performed by evaluating the radiolucent lines, cortical hypertrophy, stress shielding, osteolysis and fixation stability. Radiographic analysis of the acetabular component was performed by evaluating the osteolysis and fixation stability.

Results: The average Harris hip score improved from 54.3 points preoperatively to 95.4 points at the last follow-up. In the results of radiographic analysis of the femoral component, stable bony ingrowth was noted in thirty-eight cases and stable fibrous ingrowth was observed in one. Non-progressive radiolucency < 2 mm in width was observed in eight cases. There were three cases of osteolysis, thirty-six cases of stress shielding, and one case of cortical hypertrophy. Radiographic analysis of the acetabular component revealed stable bony ingrowth in thirty-eight cases and unstable fixation in one case. There were two cases of osteolysis.

Conclusion: The results of primary total hip arthroplasty using cementless VerSys femoral stem after a minimum of five-year follow up revealed that the rate of femoral osteolysis had decreased and the rate of bone resorption by stress shielding was relatively high. However, a longer-term follow up will be needed.
KEYWORD
Total hip replacement arthroplasty, Femoral stem, VerSys
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) ´ëÇÑÀÇÇÐȸ ȸ¿ø