Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0386720090210030272
Journal of the Korean Hip Society
2009 Volume.21 No. 3 p.272 ~ p.274
Hemiarthroplasty Using a Modular Hip Segment in a Patient with a Long Stem Total Knee Prosthesis
Lee Sung-Rak

Lee Bong-Jin
Kim Seong-Tae
Park Kwon-Hee
Abstract
Femoral neck fractures frequently occur in elderly patients and the treatment strategies for this are well documented. Revision knee arthroplasty using a long intra-medullary stem has recently been increasingly used for treating complications such as infection, aseptic loosening or instability. The current case had a femoral neck fracture with a well-fixed, long stem knee prosthesis, which reached to near the lesser trochanter of the femur. The authors performed the surgery using impaction of the modular hip segment; its inner diameter was fit to the outer diameter of the femoral stem of the knee prosthesis. At two years postoperative follow-up, the result was excellent without loosening or osteolysis.
KEYWORD
Femur neck fracture, Hemiarthroplasty, Long stem total knee prosthesis
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) ´ëÇÑÀÇÇÐȸ ȸ¿ø