A Case of Transorbital Orbital Floor Fracture Repair Assisted Endonasal Balloon Catheter
Kim Min-Joon

Kim Jung-Suk
Park Tae-Jung
Jung Tae-Young
Abstract
It is important to choose which approaches should be used to correct the fracture if the operation is indication for surgery in patients with orbital floor fracture. Transorbital, transantral, and endonasal approaches are methods for correcting the orbital floor fracture. The approach needs to be considered the location of the fracture, the degree, the severity of the fracture, the least remaining patient¡¯s disability, and preference of the surgeon. We report a case of orbital floor fracture using transorbital approach and endonasal catheter ballooning to resolve the limitations of transorbital approach alone.
KEYWORD
Blow-out fracture, Catheters, Transorbital approach