Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0390220200310020243
Journal of Clinical Otolaryngology, Head and Neck Surgery
2020 Volume.31 No. 2 p.243 ~ p.247
Two Cases of Endoscopic Reduction of Medial Orbital Blow Out Fracture Using a TnR Nasal Mesh¢ç
Park Geun-Woo

Bae Gyo-Han
Noh Woong-Jae
Jung Tae-Young
Abstract
Orbital blow out fractures can cause functional and cosmetic problems by prolapse or entrapment of the orbital tissue. Surgical intervention is performed to prevent limitation of gaze, diplopia and cosmetic disturbance.
Implant material is used to support prolapsed orbital tissue. Implant material should be selected in consideration of multiple conditions. In this study the experiences with a new surgical material for reduction of orbital blow out fracture are presented. This report suggests TNR Nasal Mesh¢ç can be new option for reduction of orbital blow out fracture.
KEYWORD
Blow out fracture, Absorbable implants
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)