Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0438520060130010171
Journal of the Korean Society of Neonatology
2006 Volume.13 No. 1 p.171 ~ p.175
A Case of Unilateral Pleural Effusion Due to Percutaneously Inserted Central Venous Catheterization
Nam Hee-Young

Lee Cho-Ae
Lee Kyu-Hyung
Abstract
Percutaneously inserted central venous catheterization (PICC) is commonly used for the management of preterm infants and surgical newborn babies to provide intravenous access for prolonged therapy and parenteral nutrition. Insertion of PICC in neonate has been associated with both immediate and late complications. The immediate complications include catheter malposition, pneumothorax and hemothorax usually secondary to the insertion procedure. Late complications are sepsis, thrombosis, catheter tip migration, vessel perforation, cardiac tamponade, pericardial effusion, pleural effusion and chemical pneumonitis. It is recognized that catheter tip migration can occur at any time with potentially fatal outcome. We report here a newborn infant that successful PICC placement was followed a few days later by the development of a unilateral pleural effusion due to migration of the cathter tip, with a brief review of the literatures. (J Korean Soc Neonatol 2006;13:171- 175)
KEYWORD
Percutaneously inserted central venous catheter, Pleural effusion
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø