Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0602720200240040203
Implantology
2020 Volume.24 No. 4 p.203 ~ p.211
Implant-Fixed Prostheses Restoration with New Retention Type Using Spread Fit Ti-Base System
Park Tae-Min

Jeong Chang-Mo
Kim So-Yun
Kim Soo-Hong
Huh Jung-Bo
Abstract
Spread Fit (SFIT) Ti-Base System was developed to overcome complications of conventional implant prosthesis system. This system uses a specific locking mechanism between the abutment and prosthesis instead of cement or screws, providing easy retrievability and no possibility of biological complications. This case report introduces clinical experience with a 3 - month follow-up of implant fixed prosthesis fabricated with SFIT Ti - Base System on a right maxillary posterior edentulous site. No biological complications or loss of retention was observed during the observation time. SFIT Ti-Base System is expected to be used in various clinical cases in the future
KEYWORD
Alveolar ridge split, Dental implant, Guided bone regeneration
FullTexts / Linksout information
 
Listed journal information