Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0604020100250030194
Korean Journal of Critical Care Medicine
2010 Volume.25 No. 3 p.194 ~ p.198
Cardiac Transplantation for a Patient with Intra-aortic Balloon Pump and Extracorporeal Membrane Oxygenator due to Cardiogenic Shock after Acute Myocardial Infarction
Lee Jae-Hang

Lee Young-Ok
Min Byoung-Ju
Yoo Byung-Su
Kim Ki-Bong
Abstract
A 66-year-old male patient who suffered from chest pain and dyspnea was admitted to our hospital. He was diagnosed as having an acute myocardial infarction, and recovered from cardiogenic shock after cardiopulmonary-cerebral resuscitation. Under the support of extracorporeal membrane oxygenator (ECMO) he underwent successful percutaneous coronary intervention. After this, an intra-aortic balloon pump (IABP) was inserted to increase coronary perfusion and reduce the impedance to left ventricular ejection. After 6 days, the patient was weaned from ECMO support; however, IABP therapy and infusion of inotropic agents were required to maintain adequate hemodynamic status. One week later, cardiac transplantation was performed successfully without major complications.
KEYWORD
acute myocardial infarction, cardiac transplantation, cardiogenic shock, extracorporeal circulatory support
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø