Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0604020130280030201
Korean Journal of Critical Care Medicine
2013 Volume.28 No. 3 p.201 ~ p.203
Foreign Body Removal at Right Main Bronchus in A Neonate
Ri Hyun-Su

Shin Sang-Wook
Baek Seung-Hoon
Kim Hye-Jin
Lee Sun-Jae
Baik Seong-Wan
Abstract
Foreign body in the airway could be a life-threatening risk, especially for young pediatric patients. A 6-day old male patient with foreign body, which was located deep in the right main bronchus was being admitted. Although we tried three times to remove it with rigid bronchoscopic forceps under the general anesthesia, we failed. Before switching to surgical treatment, we changed the Trendelenburg position and tapped his back several times in order to alter the foreign body toward the forcep. Finally we were able to catch and extract the foreign body successfully. We suggest that back percussion with the Trendelenburg position is a useful solution to remove a foreign body within a deep airway.
KEYWORD
back percussion, bronchial foreign body, posture
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø