Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0605920060120020238
Journal of Korean Association of Pediatric Surgeons
2006 Volume.12 No. 2 p.238 ~ p.243
Catheter Embolism during Chemoport Removal
Song Ki-Byung

Nam So-Hyun
Kim Dae-Yeon
Kim Seong-Chul
Kim Young-Hwue
Kim In-Koo
Abstract
Chemoport is widely used in pediatric surgery field. But various complications can occur during the process of insertion or removal of chemoport. Surgeons must be familiar with the treatment of these complications. We had one catheter cuts off during chemoport removal, become a catheter embolism. Interventional radiologic removal was successful. Verifying the length of removed catheter and careful observation of the catheter tip during removal procedure is important to prevent the possibility of catheter embolus. Radiologic intervention was accessible to remove the retained catheter.
KEYWORD
Chemoport, Catheter embolism, Intervention, Angiography
FullTexts / Linksout information
Listed journal information
KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø