Comparative Analysis of Microcystin during Water Treatment Process between Real-Time PCR and LC/MS
|
|
Park Hong-Gi
Jung Mi-Eun Cha Dong-Jin Jung Eun-Young Bean Jae-Hoon
|
|
Abstract
|
|
|
We performed a comparative analysis using a Real-time PCR (Polymerase Chain Reaction) and LC/MS (Liquid-Chromatograph/Mass Spectrometer) method in order to detect microcystin in environmental sources. Among the three different primer sets tested for microcystin using three positive strains of Microcystis aeruginosa by Real-time PCR assay, only TOX2P/TOX2M primer pairs were able to detect Microcystis aeruginosa. According to the results of a survey carried out from June 2009 to September 2009, 11 out of 11 (100%) raw water samples were were found to have microcystin when the Real-Time PCR and LC/MS method was used, with total microcystin concentration ranging from 5.98~219.0 §¶/l. A microcystin removal treatment process was used to ensure entire removal, by passing it through a BAC filtration step. It was concluded that real-time PCR assay can be used to estimate micrucystin detection more rapidly and easily than the LC/MS method.
|
|
KEYWORD
|
|
Microcystin, Real-Time PCR, LC/MS, TOX2P/TOX2M primer
|
|