Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0615720000170010027
Jouranl of Korean Acupuncture and Moxibustion society
2000 Volume.17 No. 1 p.27 ~ p.41
Study for the Deficiency and Excessiveness Diagnosis in the Front Point by Elastic State







Abstract
The meridian system is the most essential and basic connecting structure that maintains the vital activities of viscera and bowels by connecting them with each part of body¢¥s surface. Doctors can understand the healthy condition, and the region and deficiency-excessiveness of disease by observing the condition of Qi flowing.
Deficiency and excessiveness could be differentiated by various symptoms expressed in meridian system. Especially there could be several clues like pain, heat-coid, protuberance-depression, change of color and shine in the line of channel leads to the judgment of deficiency-excessiveness
The diagnosis of deficiency and excessiveness can be generalized by quantification of elastic status in skin surface along the meridian system.
By comparing data from measurement of elastic condition with those from traditional deficiency and excessiveness, it could be utilized for the development of oriental medicine. All biological activities in the human body are based on meridian system according to the oriental medicine. Also the meridian system is viewed as basic and essential structure connecting internal viscera and each part of body.
The areas of expressed channel phenomena are muscle to bone, muscle to muscle and bone to bone. These areas are called depression where meridian system is present and any changing state on those points can be measured.
It could be difficult in diagnosing the reaction of meridian system because doctor can depend on his own judgment. Therefore, it is necessary to quantify and indexate channel reactions. To quantify the channel reactions, specially manufactured instrument was used to quantify the protuberance and depression to differentiate the deficiency and excessiveness.
The results follow as below;
1. The elastic index measurement by the equipment proved a pattern of agreement showing the values that ranged within standard deviation 0.05§¸f/§¯ throughout the experiment except few cases¢¥ measurement in CV-17.
2. To evaluate the state of deficiency & excessiveness of elastic index measurements in frontal point, elastic index measurements in the front paint were compared to the elastic index measured surrounding the point within 2.5 §¯. Such result of indexing procedure was closely matched to the concept of palpitation.
3. If the elastic index values in the surrounding front point closely located to the elastic index values in the front point, the judgement on the state of deficiency and excessiveness was delayed. Otherwise, it was judged as deficiency or excessiveness.
4. Out of total 12 cases of comparing the elastic index values to the elastic index values in the surrounding front point, Three to nine front points were judged as either in the state of deficiency or excessiveness.
5. Among the nine front points judged as either in the state of deficiency or excessiveness, Four cases were matched to the electric index measured by EAV that evaluating the internal organs by five different phases.
If more clinical cases are accumulated, it is expected to systematically theorize and improve the concept of deficiency and excessiveness in the internal organs using the front point.
KEYWORD
FullTexts / Linksout information
  
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)