A Retrospective Study on Needling Depth of Hwangmun (BL51) and Jisil (BL52) with MRI
Yang Hyun-Jung

Sim Ho-Yun
Lee Kwang-Ho
Abstract
Objectives: The aim of this study is to investigate the needling depth of Hwangmun (BL51) and Jisil (BL52) retrospectively using an L-spine MRI.

Methods: We measured the shortest distance from the skin to transversalis fascia at both sides of Hwangmun and Jisil, and analyzed the difference between male and female using a student t-test, and between the left and right sides with a paired t-test.

Results: In the case of males, the average depth of left Hwangmun was 48.24 ¡¾ 10.16 mm, and that of right was 47.23 ¡¾ 9.59 mm; left Jisil was 56.91 ¡¾ 9.00 mm and right was 55.74 ¡¾ 8.75 mm. In the case of females, the average depth of left Hwangmun was 42.26 ¡¾ 9.29 mm, and that of right was 41.63 ¡¾ 9.32 mm; left Jisil was 49.21 ¡¾ 10.77 mm and right was 48.41 ¡¾ 11.38 mm. The depth of male insertion was deeper than that of female in Jisil, but there was no significant difference according to gender in Hwangmun.

Conclusion: For males, the needling depth of left Hwangmun is 37.21 ~ 68.23 mm and right is 36.91 ~ 70.50 mm while left Jisil is 42.97 ~ 70.84 mm and right is 43.75 ~ 72.00 mm For females the needling depth of left Hwangmun is 26.80 ~ 68.28 mm and right is 25.70 ~ 65.59 mm, while left Jisil is 30.94 ~ 79.06 mm and right is 28.13 ~ 77.27 mm.
KEYWORD
Hwangmun, Jisil, BL51, BL52, Needling Depth
FullTexts / Linksout information
  