KMID : 0621520150200040204
|
|
Journal of the Korean Society for Surgery of the Hand 2015 Volume.20 No. 4 p.204 ~ p.208
|
|
Extensor Digiti Minimi Triggering Caused by an Anatomical Variation: A Case Report
|
|
Roh Youn-Tae
Jeong Chang-Hoon Kang Soo-Hwan Lee Jae-Young Jeon Sang-Hyun Park Il-Jung
|
|
Abstract
|
|
|
Although flexor tendon triggering due to stenosing flexor tenosynovitis is common clinically, extensor triggering is quite rare. Known common causes are impingement between extensor tendon and extensor retinaculum, stenosis of the tendon sheath, and impingement between extensor tendon and osteophyte. We report rare case of triggering in the little finger caused by impingement between extensor digiti minimi and synovial septum.
|
|
KEYWORD
|
|
Trigger finger, Extensor digiti minimi, Extensor tendon
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|