Results of Iliac Bone Graft with Kirschner Wire Fixation for Scaphoid Nonunions
Kim Byoung-Jin

Lim Gil-Hwan
Kim Myung-Sun
Abstract
Purpose: To determine clinical and radiographic results of iliac bone grafting with Kirschner wire fixation for treatment of scaphoid nonunions.

Methods: A total of 13 patients who had scaphoid nonunion treated with iliac bone grafting and Kirschner wire fixation between October 2007 and January 2016 were enrolled as subjects of this study. Their clinical results were evaluated, including range of motion of the wrist joint and modified Mayo wrist score. Radiographic results including lateral intrascaphoid angle and scapholunate angle were also assessed.

Results: Bony union was achieved in 11 (84.6%) of 13 cases. Modified Mayo wrist score was improved from 64.0 preoperatively to 87.5 postoperatively. Average intrascaphoid angle was improved from 39.5¡Æ preoperatively to 27.2¡Æ postoperatively while scapholunate angle was improved from 66.0¡Æ preoperatively to 55.1¡Æ postoperatively.

Conclusion: Iliac bone graft with Kirschner wire fixation provided good clinical and radiographic results. Therefore, iliac bone graft with Kirschner wire fixation can be considered as a good treatment option for scaphoid nonunion.
KEYWORD
Scaphoid, Nonunion, Kirschner wire, Bone graft