Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0828620060100010087
Journal of Korean Arthroscopy Society
2006 Volume.10 No. 1 p.87 ~ p.90
The Delayed Inflammatory Reaction after Anterior Cruciate Lligment Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report-
Lim Hong-Chul

Yang Jae-Hyuk
Noh Kyoung-Sun
Abstract
The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw (Bioscrew¢ç) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.
KEYWORD
Anterior cruciate ligament, Bioabsorbable interference screw, Inflammatory reation
FullTexts / Linksout information
Listed journal information