Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients.

Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained.

Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.