Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0828620100140020131
Journal of Korean Arthroscopy Society
2010 Volume.14 No. 2 p.131 ~ p.134
Biodegradable Meniscus Screw Fixation of Thin Flap Osteochondral Fracture - Two Case Report -
Chon Je-Gyun

Sun Doo-Hoon
Song In-Soo
Kim Young-Woo
Jung Jae-Yong
Lee Bong-Ju
Abstract
Inappropriate treatment of osteochondral fracture can cause osteoarthritis, pain, functional disorder. With large osteochondral fracture, reduction and fixation of the fragment using metal implant. However, when the bone fragment had less than 2mm, the fragment extracted because of difficulty of fragment fixation. Authors treated patients with fracture fragment thickness less than 2mm of osteochondral dissecans in medial femoral condyle and patella fracture using biodegradable meniscus screw, and then we obtained good result.
KEYWORD
Knee, Thin flap osteochondral fracture, Biodegradable meniscus screw
FullTexts / Linksout information
Listed journal information