Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0829220170410040147
Korean Journal of Oral and Maxillofacial Pathology
2017 Volume.41 No. 4 p.147 ~ p.153
Menton Deviation in Angle Measurement on Posteroanterior Cephalogram and Computed Tomography
Yoon Suk-Ja

Kang Byung-Cheol
Lee Jae-Seo
Jin Mun-Hwan
Lee Eun-Joo
Abstract
This study aimed to compare chin deviation in angle measurement on posteroanterior(PA) cephalogram and computed tomography (CT). Chin deviation was assessed as menton(Me) deviation in angle measurement on PA cephalogram and CT images of 35 patients who had orthognathic surgery (19 male and 16 female with average age of 22.1¡¾3.33yr). The difference between the Me deviation was calculated and statistical analysis was performed to compare the deviation direction and asymmetry severity on the two imaging modalities. There was statistically significant difference in the difference of Me deviation between PA cephalogram and CT by one-simple t-test (p<.05). The mean difference of Me deviation was 2.21¡Æ¡¾ 1.84¡Æ. The maximum difference of Me deviation was 8.64¡Æ. There were statistical agreements in the deviation direction (k =0.82, p<.05) and in the severity of facial asymmetry (k =0.37, p<.05). The difference of the deviation direction was detected in 2 patients (5.71 %). The difference of the severity of facial asymmetry was in 15 patients (42.86%). The chin deviation in angle measurement might be different between PA cephalogram and CT in some patients.
KEYWORD
Facial Asymmetry, Anatomic Landmarks, PA cephalogram, CT Tomography, X-Ray Computed
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)