Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0829320170200040097
Korean Journal of Clinical Microbiology
2017 Volume.20 No. 4 p.97 ~ p.102
Evaluation of EuDxTM-PN MLC Detection Kit for Detection of Mycoplasma pneumoniae, Chlamydophila pneumoniae, and Legionella pneumophila in Respiratory Specimens
Lee Mi-Kyung

Sung Heung-Sup
Cho Ah-Ra
Chi Hyun-Young
Abstract
Background: Infection by the intracellular bacteria Mycoplasma pneumoniae, Chamydophila pneumoniae, and Legionella pneumophila are common causes of community-acquired pneumonia (CAP). This study describes the evaluation of a new multiplex real-time PCR test, EuDxTM-PN MLC Detection Kit (EUDIPIA), which allows the simultaneous detection of M. pneumoniae, C. pneumoniae, and L. pneumophila in respiratory samples.

Methods: A total of 353 samples were tested using three PCR kits: multiplex PCR (Seeplex PneumoBacter ACE Detection Kit) and two multiplex real-time PCR (EuDxTM-PN MLC Detection Kit and AnyplexTM II RB5 Detection Kit). The results were considered true positives (expanded standard) for M. pneumoniae, C. pneumoniae, and L. pneumophila if they were positive according to any of the three tests.

Results: The sensitivity and specificity of EuDxTM-PN MLC Detection Kit were 93.3-100% and 100%, respectively. The agreement rate and Cohen¡¯s kappa coefficient (value) between EuDxTM-PN MLC Detection Kit and AnyplexTM II RB5 Detection Kit for M. pneumoniae, C. pneumoniae, and L. pneumophila were 70-100% and 0.82-1, respectively.

Conclusion: These results demonstrate that the EuDxTM-PN MLC Detection Kit is a sensitive, specific, and useful screening tool for the detection of atypical pathogens in respiratory samples and can be helpful in selecting appropriate antimicrobial therapy for patients with respiratory infection.
KEYWORD
Chamydophila pneumoniae, Legionella pneumophila, Real-time polymerase chain reaction, Mycoplasma pneumoniae, Respiratory tract infection
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø