Management of Split Thickness Skin Graft Donor Sites: Comparison of Different Dressing Materials
Lee Eun-Jeoung

Kim Jae-Ok
Hwang Tae-Sik
Shin Myung-Ha
Jeon Chang-Won
Abstract
Purpose: The purpose of management of the donor is to maintain a moist condition that promotes healing process and prevents pain, infection. We have performed a prospective study to compare the usefulness between Aquacel Ag? and Mepitel?.

Methods: 36 consecutive patients, in whom STSG was performed, were included into the study. STSG are harvested as a usual manner and the donor site are dressed with Aquacel Ag? or Mepitel?, alternatively. The usefulness are compared with re-epithelialization, pain, frequency to change the second dressing, and ease of application.

Results: There are no differences in the days of re-epithelialization, pain perception of patients, but significantly differences in frequency to change the second dressing, and ease of application. Aquacel Ag? is better than Mepitel?.

Conclusion: We concluded that Aquacel Ag? dressing is better than Mepitel? for STSG donor site just in the frequency to change the second dressing and ease of application.