Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0858320080110020137
Journal of the Korean Shoulder Elbow Society
2008 Volume.11 No. 2 p.137 ~ p.142
Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture
Ha Sung-Sik

Sim Jae-Chun
Hong Ki-Do
Kang Jung-Ho
Kim Jae-Young
Park Kwang-Hee
Abstract
Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP).

Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer¡¯s evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method.

Results: The mean time for bone union was 11.9 weeks. Using the Neer¡¯s functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient).

Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.
KEYWORD
Humerus, Proximal Humerus Fracture, Locking Compression Plate
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø