Abstract
|
|
|
Purpose: To evaluate the results of the compression plate fixation and autogenous bone graft in the management of humerus shaft nonunion.
Materials and Methods : Eighteen cases were treated for humerus shaft nonunion using compression plate fixation and an autogenous iliac bone graft. The mean follow-up period was 28 months. Bony union was confirmed from the serial radiographs and the clinical outcomes were assessed according to ASES scoring system.
Results: In 12 cases of initial plate fixation, the causes of nonunion were 6 cases of inadequate plate length, 2 with a broken plate, 2 with screw loosening, 1 infection and 1 noncompliance of a psychiatric patient. In 3 cases of initial intramedullary fixation, the cause of nonunion was a distraction of the fracture site. In 3 cases of external fixation, the cause of nonunion was inadequate fixation. All cases showed bony union after an average of 24 weeks. The clinical outcomes were 11 excellent, 6 good and 1 fair.
Conclusion: In the treatment for nonunion, compression plate fixation with autogeneous bone graft after complete removal of the fibrous and necrotic tissue is believed to give satisfactory results.
|
|
KEYWORD
|
|
Humerus shaft, Nonunion, Compression plate fixation, Autogenous bone graft
|
|