Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0858320100130010127
Journal of the Korean Shoulder Elbow Society
2010 Volume.13 No. 1 p.127 ~ p.131
Arthroscopy Assisted Percutaneous Reduction and Screw Fixation of a Displaced Intra-articular Glenoid Fracture - A Case Report -
Ko Sang-Hun

Jeon Hyung-Min
Shin Seung-Myeong
Abstract
Purpose: The authors used arthroscopy-assisted percutaneous reduction and cannulated screw fixation rather? than conventional arthrotomy for displaced glenoid fracture.

Materials and Methods: We used arthroscopy assisted reduction and screw fixation for a 66 year old man who had a clavicle fracture, a displaced glenoid fracture and a scapula fracture.

Results: At 9 months postoperatively, the patient had recovered full range of motion and was not inconvenienced by the surgery. Removal of the implant was done 12 months post-operatively under general anesthesia.

Conclusion: The advantages of arthroscopy-assisted percutaneous screw fixation are less pain and less bleeding, shorter hospital stay and earlier rehabilitation. Arthroscopic percutaneous screw fixation for a displaced glenoid fracture seems to be a good alternative treatment method.
KEYWORD
Glenoid, Displaced fracture, Arthroscopy, Percutaneous fixation, Cannulated screw
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø