Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0858320130160010027
Journal of the Korean Shoulder Elbow Society
2013 Volume.16 No. 1 p.27 ~ p.32
The Treatment of Humerus Shaft Simple Fracture by MIPO Technique
Ko Sang-Hun

Lee Seon-Ho
Cho Bum-Keun
Abstract
Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons¡¯ score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.
KEYWORD
Humerus shaft simple fracture, Minimally invasive percutaneous osteosynthesis, Locking compression plate
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø