Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0860920090110010024
Journal of the Korean Association EMG-Electrodiagnostic Medicine
2009 Volume.11 No. 1 p.24 ~ p.29
Reference Value of Pediatric Visual Evoked Potential
Kim Hyung-Kyun

Park Yoon-Ghil
Moon Jae-Ho
Choi Won-Ah
Choi Jung-Hwa
Abstract
Objectives: To establish the reference range of latency values in pediatric patients according to their age.

Methods: Visual evoked potential was performed on children between age 0 and 10, diagnosed with unilateral
amblyopia at GangNam Severance Hospital between January 2005 and December 2008. Latency values for N1, P1, N2, P2, N3 were measured for the intact and the amblyopian eye.

Results: For the intact eye the mean values of latency of were N1=31.6 ms, P1=50.8 ms, N2=80.0 ms,
P2=113.3 ms, N3=160.3 ms and for the amblyopian eye they were N1=35.4 ms, P1=56.1 ms, N2=81.1ms, P2=113.8 ms, N3=160.8 ms. There were no significant differences between the intact eye and the amblyopian eye. Compared to the normal values in adults, the mean values of latency was shorter for N1 and P1, and longer for N2, P2, and N3. These differences were statistically significant.

Conclusion: This study showed that reference values of latency in visual evoked potential were different in children compared to the values in adults.
KEYWORD
Visual evoked potential, Children, Reference value, Amblyopia
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) ´ëÇÑÀÇÇÐȸ ȸ¿ø