Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0869120160180040257
±âÃÊ°£È£ÀÚ¿¬°úÇÐȸÁö
2016 Volume.18 No. 4 p.257 ~ p.263
Impact of Central Line Insertion Bundle on the Adherence of Bundle and Central Line-Associated Bloodstream Infections in the Operating Room
Shin Eun-Jung

Jeong Jae-Sim
Choi Sang-Ho
Huh In-Young
Abstract
Background: This study purposed to examine how the incidence of the central line-associated bloodstream infection (CLABSI) in a operating room (OR) is affected by bundle application on central line insertion (CLI) practice.

Methods: The study design was a pretest-posttest experimental trial. The subjects were 83 patients before the bundle application on CLI and 70 patients after.

Results: The compliance(%) of bundle on CLI of among those who observed all of the five items increased from 7.2% before the intervention to 72.9% after. By items, compliance with the maximal barrier precaution was 100% for the use of a mask and cap before and after the intervention, but increased from 73.5% before the intervention to 88.6% after for the hand hygiene, from 73.5% to 88.6% for the use of a sterile gown, and from 9.6% to 75.7% for the use of a sterile large drape covering the whole body. CLABSI did not happen on CLI either before or after the application of the bundle intervention.
Conclusion: Bundle application increased compliance with the use of a sterile gown and the use of a sterile large drape. However, its effect in the prevention of CLABSI was not clear probably due to the short period of intervention in a single hospital.
KEYWORD
Central line?associated bloodstream infection, Central line insertion bundle, Operating room, Infection control
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed