Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0869619980150040530
Journal of Korean Society of Hospital Pharmacists
1998 Volume.15 No. 4 p.530 ~ p.534
Weight Loss of Tablet by Operating Automatic Tablet Counter
È«ÇýÁ¤/Hong, Hye Jung
À̹̰æ/½Å¼þÈÖ/ÁÖ¼ö¸¸/±è³²Àç/¼Ûº¸¿Ï/±èÁ¾¿ì/Lee, Mi Kyung/Shin, Soong Hui/Joo, Soo Man/Kim, Nam Jae/Song, Bo Wan/Kim, Jong Woo
Abstract
While operating automatic tablet counter(ATC), there were filling error and filling time delay due to the breaking of tablets. This was presumed to happen mostly to uncoated tablet. This research was performed to show the adequate dosage form to operate ATC efficiently. As methods, error of stuck pills was analyzed by dosage form, distribution of dosage forms in ATC was examined in Korea and Japan. Stability was studied in terms of physical strength such as hardness and friability. The results show that 54% of stuck pills in the cassette of ATC during operation was uncoated tablet. The proportion of uncoated tablet, coated tablet, capsule in ATC was 67%, 34%, 19%, respectively in Korea, and was 9%, 64%, 26% respectively in Japan. The stability test of physical strength shows when the hardness were 1.5, 3.7, 6.6(§¸/cm2), the weight loss were 1.29%, 0.72%m 0.24% and when the friability 0.19%, 0.27%, 0.48%, the weight loss were 0.93%, 1.45%, 1.82%.
KEYWORD
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)