Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0882420080750040436
Korean Journal of Medicine
2008 Volume.75 No. 4 p.436 ~ p.443
Clinical usefulness of biofilm formation and associated genes with staphylococcus epidermidis blood isolates
Park Kyung-Hwa

Chio Su-Mi
Jung Sook-In
Shin Jong-Hee
Abstract
Background/Aims: To evaluate the clinical usefulness of biofilm production and related genes for discriminating
between pathogens, colonizers, and contaminants with Staphylococcus epidermidis blood isolates.

Methods: Forty S. epidermidis blood isolates, including 19 pathogens, 11 colonizers, and 10 contaminants, were tested. Biofilm production was determined in 96-well polystyrene microtiter plates using crystal violet staining. Relative units (rU), given by the optical density (OD) of the clinical isolates divided by the OD of a standard biofilm-negative strain,
were used for quantification. Polymerase chain reactions for the icaABCD, atlE, and aap genes were performed to
evaluate biofilm-related genes. The diagnostic accuracy of biofilm-related genes was assessed using the sensitivity,
specificity, and positive predictive value.

Results: Biofilm production of the catheter-related isolates, including pathogens and colonizers, was significantly greater than that of contaminants (50% vs. 20%, p=0.012). For catheter-related isolates, rU was significantly greater for
ica-positive isolates than for ica-negative isolates (1.72¡¾0.84 vs.0.94¡¾0.22; p=0.003). The prevalence of atlE and aap did
not differ between the three groups. Seven S. epidermidis were isolated together with other microorganisms from
intravascular catheters, and their biofilm production was relatively low. The positive predictive value of icaABCD was
83% for discriminating between catheter-related isolates and contaminants.

Conclusions: Pathogens and colonizers had similar biofilm production capacities and prevalences of related genes, whereas catheter-related isolates and contaminants differed. The biofilm production ability and presence of these genes cannot be used for clinical decision-making regarding true pathogens. The ica operon might be useful for differentiating between contaminants and catheter-related isolates in catheter-related infection (CRI). Further studies of other related genes and protein expression are needed to assess the clinical usefulness of biofilm production for clinical isolates.
KEYWORD
Catheter related infection, Staphylococcus epidermidis, Biofilm
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø